Configuring Serial Ports [OSD]
446
AlterPath OnSite Administrators and Users Guide
Configuring Serial Ports [OSD]
An administrative user can use the “Serial Ports” screen to configure serial
ports as follows:
Choose a connection protocol: telnet, ssh, raw, or power management
Enable or disable one or all serial ports
Assign an alias to one serial port at a time
Enable power management on a serial port by an administrator who is
connected to the serial port
Set the baud rate for one or all serial ports
Set user and group access permissions for one or all serial ports
Set authentication for one or all serial ports
See “To Select a Serial Port or Ports to be Configured [OSD]” on page 446 for
how to start and for links to the procedures for performing the previously-
listed tasks.
T To Select a Serial Port or Ports to be
Configured
[OSD]
1. Go to: Configure>Serial ports.
The Serial ports screen appears with a list of all the serial ports and an
option called “All ports.”
2. To select a port or all ports, do one of the following:
Type the first letters of the port name until the desired port is
highlighted in the list or type capital A to highlight “All ports”
The port name field is case-sensitive.
or
Select the desired port name or “All ports” from the list.
Note: Selecting “All ports” allows you to configure all ports the same.
3. Press Enter.